An Unbiased View of Iontophoresis

Based on the suffering and the health of an individual, device selection often performs a decisive function in the possible therapeutic achievement. With appropriate devices selection you have a very high probability of success with an iontophoresis gadget to dry. Not necessarily with treatment strictly regarding to manual a success (independence from sweat) is usually reached. In this case, we are of training course and especially following the purchase of program – with this experience since 1999 in neuro-scientific iontophoresis – aside. With the technique Iontophoresis, many have the ability to “get dry”.

really great feeling when hands / foot / armpits are dried out and warm instead of wet and frosty (frog hands). Still, many users delivered their iontophoresis device back – why? We also asked ourselves this issue, above all because we are also thinking about providing our customers with optimum and effective therapy.

Background information: There are two types of treatment streams: Pulse and DC. DC products deliver the result of greater performance (sweat resistance) with the same current setting. Right now you could come to the conclusion: Fine, I’m sweating greatly, so DC is better for me personally, and cheaper it really is! Unfortunately this is simply not always correct: the treatment with pulse current products is merely more enjoyable with the same current setting. As a result, with a pulse-current gadget, you could drive higher currents when compared to direct current, because the current is better tolerated.

Nevertheless, the limit values ​​must not become exceeded (Dr. Hoenle specifies a maximum of 25 mA for your feet, 15 mA for the hands and 5 mA for the treating the underarms as a limit). These values ​​are not normally attained with immediate current products, unless the individual is very insensitive to the procedure stream, which is very rare, nevertheless, and the skin must also join the complete. Even on your toes, 30 mA DC is a phrase! When you can set 5 mA with a pulse power device under the armpits, this might be more than enough to record successful since the skin there is quite thin (and unfortunately sensitive) and for that reason doesn’t need higher currents. Specifically with the armpits, DC devices can sometimes tolerate just 1mA and thus in some cases no therapeutic success may be accomplished. The same pertains to the hands, where you often have minor injuries (nail, etc.) where not only direct currents can be very painful. It is not so much the topic of your feet, but also the guideline of the word: The pulse current is usually often a lot more pleasant there as well.

Leave a Reply

Your email address will not be published. Required fields are marked *

*